DELL EMC PowerScale: Isilon: Gen6更换rise卡电池后微码升级

张开发
2026/4/18 18:04:16 15 分钟阅读

分享文章

DELL EMC PowerScale: Isilon: Gen6更换rise卡电池后微码升级
DELL EMC PowerScale: Isilon: Gen6更换rise卡电池后微码升级1、用命令查看电池状态isi batterystatus listISILON-Web-1# isi batterystatus listLnn Status1 Status2 Result1 Result21 Internal fault N/A passed N/A2 Ready, enabled, and fully charged N/A passed N/A3 Ready and enabled N/A passed N/A4 Ready and enabled N/A passed N/A2、节点关机,更换rise卡电池,更换完成后等节点启动在使用isi batterystatus list查看电池状态,可以看到状态为Not ready(也有可能会是其他状态,只要不是ready enabled就是还有问题)ISILON-Web-1# isi batterystatus listLnn Status1 Status2 Result1 Result21 Not ready and enabled N/A passed N/A2 Ready, enabled, and fully charged N/A passed N/A3 Ready and enabled N/A passed N/A4 Ready and enabled N/A passed N/A3、查看节点微码信息isi upgrade cluster firmware devices,可